Products - JEAN MÜLLER (2024)

Type designation: SL2-3x/3A/RTU/3W/1/250-1

Article number: L223107001Z00

Descriptionaccording to EN60947-3, size NH2 - 400A
- 1pole switchable, DELTA-contact system
- for mounting on 3pole busbar system with 185mm centre-to-centre distance
- with screw terminal M12
- 3 current-transformer 250-1 mounted and wired
- with integrated measuring system PLPLANO
- 3-phase for current, voltage, power, power factor, energy [kWh]
- integrated four-quadrant energy meter with detection of the energy flow direction
- secondary current detection via current transformers, if necessary for on-site exchange / retrofitting
- wired and routed to interface module
- wired with internally protected voltage tap, routed to the interface module
- Data interface protocol: ModBus / RTU
- with point-symmetrical and reverse-polarity protected plug connection
- Number of bus users: <= 16
- Installation dimension L2 until top edge of the strip (including data interface): <= 310mm
- Measuring system can be replaced without tools

Rated operating current Ie: 250 A
Cable terminal: Flat terminal M12
Poles: 3
Switching mode: 1pole switchable
Current measurement: Integrated, 3phase
number of current-transformer: 3
Primary current of current-transformer: 250 A
Secondary rated current transformer Isr: 1 A
Datenerfassungsmodul PLPlano:

ModBus/RTU

Elektrische Kenngrößen

  • Spannungsversorgung: DC24V (+/– 6V)
  • Leistungsaufnahme: 1,5 VA
  • Innenwiderstand: L – L: 6MΩ L – N: 6MΩ
  • Messbereich L – N: AC230V (+/– 10%)
  • Messbereich L – L: AC400V (+/– 10%)
  • Frequenz: 45 – 65Hz
  • Stromwandlersekundärstrom: 1A/3 Kanäle
  • Norm: EN 61000-6-2
  • Stoßspannung: 2kV – 1,2/50µs
  • Funkstörfeldstärke: Klasse A, B
  • Luftentladung: 8kV
  • Kontaktentladung: 4kV
Schnittstelle Anschlüsse
  • ModBus/RTU: APS V1.1b
  • Physikalische Verbindung: USB-C
  • Busteilnehmer: 16
  • Neutralleiteranschluss: 2x 0,5mm²

Anzeige

  • Bereitschaft: LED Grün
  • Fehler: LED Rot

Type designation: SL2-3x/3A/RTU/3W/1/250-1

Article number: L223107001Z00

Descriptionaccording to EN60947-3, size NH2 - 400A
- 1pole switchable, DELTA-contact system
- for mounting on 3pole busbar system with 185mm centre-to-centre distance
- with screw terminal M12
- 3 current-transformer 250-1 mounted and wired
- with integrated measuring system PLPLANO
- 3-phase for current, voltage, power, power factor, energy [kWh]
- integrated four-quadrant energy meter with detection of the energy flow direction
- secondary current detection via current transformers, if necessary for on-site exchange / retrofitting
- wired and routed to interface module
- wired with internally protected voltage tap, routed to the interface module
- Data interface protocol: ModBus / RTU
- with point-symmetrical and reverse-polarity protected plug connection
- Number of bus users: <= 16
- Installation dimension L2 until top edge of the strip (including data interface): <= 310mm
- Measuring system can be replaced without tools

Rated operating current Ie 250 A
Cable terminal Flat terminal M12
Poles 3
Switching mode 1pole switchable
Current measurement Integrated, 3phase
number of current-transformer 3
Primary current of current-transformer 250 A
Secondary rated current transformer Isr 1 A
Datenerfassungsmodul PLPlano

ModBus/RTU

Elektrische Kenngrößen

  • Spannungsversorgung: DC24V (+/– 6V)
  • Leistungsaufnahme: 1,5 VA
  • Innenwiderstand: L – L: 6MΩ L – N: 6MΩ
  • Messbereich L – N: AC230V (+/– 10%)
  • Messbereich L – L: AC400V (+/– 10%)
  • Frequenz: 45 – 65Hz
  • Stromwandlersekundärstrom: 1A/3 Kanäle
  • Norm: EN 61000-6-2
  • Stoßspannung: 2kV – 1,2/50µs
  • Funkstörfeldstärke: Klasse A, B
  • Luftentladung: 8kV
  • Kontaktentladung: 4kV
Schnittstelle Anschlüsse
  • ModBus/RTU: APS V1.1b
  • Physikalische Verbindung: USB-C
  • Busteilnehmer: 16
  • Neutralleiteranschluss: 2x 0,5mm²

Anzeige

  • Bereitschaft: LED Grün
  • Fehler: LED Rot

Type designation: SL2-3x/3A/RTU/3W/1/400-1

Article number: L223107004Z00

Descriptionaccording to EN60947-3, size NH2 - 400A
- 1pole switchable, DELTA-contact system
- for mounting on 3pole busbar system with 185mm centre-to-centre distance
- with screw terminal M12
- 3 current-transformer 400-1 mounted and wired
- with integrated measuring system PLPLANO
- 3-phase for current, voltage, power, power factor, energy [kWh]
- integrated four-quadrant energy meter with detection of the energy flow direction
- secondary current detection via current transformers, if necessary for on-site exchange / retrofitting
- wired and routed to interface module
- wired with internally protected voltage tap, routed to the interface module
- Data interface protocol: ModBus / RTU
- with point-symmetrical and reverse-polarity protected plug connection
- Number of bus users: <= 16
- Installation dimension L2 until top edge of the strip (including data interface): <= 310mm
- Measuring system can be replaced without tools

Rated operating current Ie: 400 A
Cable terminal: Flat terminal M12
Poles: 3
Switching mode: 1pole switchable
Current measurement: Integrated, 3phase
number of current-transformer: 3
Primary current of current-transformer: 400 A
Secondary rated current transformer Isr: 1 A
Precision of category of the current transformers: Class 1
Datenerfassungsmodul PLPlano:

ModBus/RTU

Elektrische Kenngrößen

  • Spannungsversorgung: DC24V (+/– 6V)
  • Leistungsaufnahme: 1,5 VA
  • Innenwiderstand: L – L: 6MΩ L – N: 6MΩ
  • Messbereich L – N: AC230V (+/– 10%)
  • Messbereich L – L: AC400V (+/– 10%)
  • Frequenz: 45 – 65Hz
  • Stromwandlersekundärstrom: 1A/3 Kanäle
  • Norm: EN 61000-6-2
  • Stoßspannung: 2kV – 1,2/50µs
  • Funkstörfeldstärke: Klasse A, B
  • Luftentladung: 8kV
  • Kontaktentladung: 4kV
Schnittstelle Anschlüsse
  • ModBus/RTU: APS V1.1b
  • Physikalische Verbindung: USB-C
  • Busteilnehmer: 16
  • Neutralleiteranschluss: 2x 0,5mm²

Anzeige

  • Bereitschaft: LED Grün
  • Fehler: LED Rot

Type designation: SL2-3x/3A/RTU/3W/1/400-1

Article number: L223107004Z00

Descriptionaccording to EN60947-3, size NH2 - 400A
- 1pole switchable, DELTA-contact system
- for mounting on 3pole busbar system with 185mm centre-to-centre distance
- with screw terminal M12
- 3 current-transformer 400-1 mounted and wired
- with integrated measuring system PLPLANO
- 3-phase for current, voltage, power, power factor, energy [kWh]
- integrated four-quadrant energy meter with detection of the energy flow direction
- secondary current detection via current transformers, if necessary for on-site exchange / retrofitting
- wired and routed to interface module
- wired with internally protected voltage tap, routed to the interface module
- Data interface protocol: ModBus / RTU
- with point-symmetrical and reverse-polarity protected plug connection
- Number of bus users: <= 16
- Installation dimension L2 until top edge of the strip (including data interface): <= 310mm
- Measuring system can be replaced without tools

Rated operating current Ie 400 A
Cable terminal Flat terminal M12
Poles 3
Switching mode 1pole switchable
Current measurement Integrated, 3phase
number of current-transformer 3
Primary current of current-transformer 400 A
Secondary rated current transformer Isr 1 A
Precision of category of the current transformers Class 1
Datenerfassungsmodul PLPlano

ModBus/RTU

Elektrische Kenngrößen

  • Spannungsversorgung: DC24V (+/– 6V)
  • Leistungsaufnahme: 1,5 VA
  • Innenwiderstand: L – L: 6MΩ L – N: 6MΩ
  • Messbereich L – N: AC230V (+/– 10%)
  • Messbereich L – L: AC400V (+/– 10%)
  • Frequenz: 45 – 65Hz
  • Stromwandlersekundärstrom: 1A/3 Kanäle
  • Norm: EN 61000-6-2
  • Stoßspannung: 2kV – 1,2/50µs
  • Funkstörfeldstärke: Klasse A, B
  • Luftentladung: 8kV
  • Kontaktentladung: 4kV
Schnittstelle Anschlüsse
  • ModBus/RTU: APS V1.1b
  • Physikalische Verbindung: USB-C
  • Busteilnehmer: 16
  • Neutralleiteranschluss: 2x 0,5mm²

Anzeige

  • Bereitschaft: LED Grün
  • Fehler: LED Rot

Type designation: SL2-3x/9/KM2G-F/RTU/3W/1/400-1

Article number: L229607005Z00

Descriptionaccording to EN60947-3, size NH2 - 400A
- 1pole switchable, DELTA-contact system
- for mounting on 3pole busbar system with 185mm centre-to-centre distance
- with v-terminal and steel-frame clamp type KM2G-F, max. clamping range: 25-240mm²
- 3 current-transformer 400-1 mounted and wired
- with integrated measuring system PLPLANO
- 3-phase for current, voltage, power, power factor, energy [kWh]
- integrated four-quadrant energy meter with detection of the energy flow direction
- secondary current detection via current transformers, if necessary for on-site exchange / retrofitting
- wired and routed to interface module
- wired with internally protected voltage tap, routed to the interface module
- Data interface protocol: ModBus / RTU
- with point-symmetrical and reverse-polarity protected plug connection
- Number of bus users: <= 16
- Installation dimension L2 until top edge of the strip (including data interface): <= 310mm
- Measuring system can be replaced without tools

Rated operating current Ie: 400 A
Cable terminal: V box terminal KM2G-F 25-240mm²
Poles: 3
Switching mode: 1pole switchable
Current measurement: Integrated, 3phase
number of current-transformer: 3
Primary current of current-transformer: 400 A
Secondary rated current transformer Isr: 1 A
Precision of category of the current transformers: Class 1
Datenerfassungsmodul PLPlano:

ModBus/RTU

Elektrische Kenngrößen

  • Spannungsversorgung: DC24V (+/– 6V)
  • Leistungsaufnahme: 1,5 VA
  • Innenwiderstand: L – L: 6MΩ L – N: 6MΩ
  • Messbereich L – N: AC230V (+/– 10%)
  • Messbereich L – L: AC400V (+/– 10%)
  • Frequenz: 45 – 65Hz
  • Stromwandlersekundärstrom: 1A/3 Kanäle
  • Norm: EN 61000-6-2
  • Stoßspannung: 2kV – 1,2/50µs
  • Funkstörfeldstärke: Klasse A, B
  • Luftentladung: 8kV
  • Kontaktentladung: 4kV
Schnittstelle Anschlüsse
  • ModBus/RTU: APS V1.1b
  • Physikalische Verbindung: USB-C
  • Busteilnehmer: 16
  • Neutralleiteranschluss: 2x 0,5mm²

Anzeige

  • Bereitschaft: LED Grün
  • Fehler: LED Rot

Type designation: SL2-3x/9/KM2G-F/RTU/3W/1/400-1

Article number: L229607005Z00

Descriptionaccording to EN60947-3, size NH2 - 400A
- 1pole switchable, DELTA-contact system
- for mounting on 3pole busbar system with 185mm centre-to-centre distance
- with v-terminal and steel-frame clamp type KM2G-F, max. clamping range: 25-240mm²
- 3 current-transformer 400-1 mounted and wired
- with integrated measuring system PLPLANO
- 3-phase for current, voltage, power, power factor, energy [kWh]
- integrated four-quadrant energy meter with detection of the energy flow direction
- secondary current detection via current transformers, if necessary for on-site exchange / retrofitting
- wired and routed to interface module
- wired with internally protected voltage tap, routed to the interface module
- Data interface protocol: ModBus / RTU
- with point-symmetrical and reverse-polarity protected plug connection
- Number of bus users: <= 16
- Installation dimension L2 until top edge of the strip (including data interface): <= 310mm
- Measuring system can be replaced without tools

Rated operating current Ie 400 A
Cable terminal V box terminal KM2G-F 25-240mm²
Poles 3
Switching mode 1pole switchable
Current measurement Integrated, 3phase
number of current-transformer 3
Primary current of current-transformer 400 A
Secondary rated current transformer Isr 1 A
Precision of category of the current transformers Class 1
Datenerfassungsmodul PLPlano

ModBus/RTU

Elektrische Kenngrößen

  • Spannungsversorgung: DC24V (+/– 6V)
  • Leistungsaufnahme: 1,5 VA
  • Innenwiderstand: L – L: 6MΩ L – N: 6MΩ
  • Messbereich L – N: AC230V (+/– 10%)
  • Messbereich L – L: AC400V (+/– 10%)
  • Frequenz: 45 – 65Hz
  • Stromwandlersekundärstrom: 1A/3 Kanäle
  • Norm: EN 61000-6-2
  • Stoßspannung: 2kV – 1,2/50µs
  • Funkstörfeldstärke: Klasse A, B
  • Luftentladung: 8kV
  • Kontaktentladung: 4kV
Schnittstelle Anschlüsse
  • ModBus/RTU: APS V1.1b
  • Physikalische Verbindung: USB-C
  • Busteilnehmer: 16
  • Neutralleiteranschluss: 2x 0,5mm²

Anzeige

  • Bereitschaft: LED Grün
  • Fehler: LED Rot

Type designation: SL2-3x/9/RM300/RTU/3W/1/250-1

Article number: L229907003Z00

Descriptionaccording to EN60947-3, size NH2 - 400A
- 1pole switchable, DELTA-contact system
- for mounting on 3pole busbar system with 185mm centre-to-centre distance
- with v-terminal and aluminium box clamp clamp type RM300, max. clamping range: 25-300mm²
- 3 current-transformer 250-1 mounted and wired
- with integrated measuring system PLPLANO
- 3-phase for current, voltage, power, power factor, energy [kWh]
- integrated four-quadrant energy meter with detection of the energy flow direction
- secondary current detection via current transformers, if necessary for on-site exchange / retrofitting
- wired and routed to interface module
- wired with internally protected voltage tap, routed to the interface module
- Data interface protocol: ModBus / RTU
- with point-symmetrical and reverse-polarity protected plug connection
- Number of bus users: <= 16
- Installation dimension L2 until top edge of the strip (including data interface): <= 310mm
- Measuring system can be replaced without tools

Rated operating current Ie: 250 A
Cable terminal: V-type aluminium box terminal RM300
Poles: 3
Switching mode: 1pole switchable
Current measurement: Integrated, 3phase
number of current-transformer: 3
Primary current of current-transformer: 250 A
Secondary rated current transformer Isr: 1 A
Datenerfassungsmodul PLPlano:

ModBus/RTU

Elektrische Kenngrößen

  • Spannungsversorgung: DC24V (+/– 6V)
  • Leistungsaufnahme: 1,5 VA
  • Innenwiderstand: L – L: 6MΩ L – N: 6MΩ
  • Messbereich L – N: AC230V (+/– 10%)
  • Messbereich L – L: AC400V (+/– 10%)
  • Frequenz: 45 – 65Hz
  • Stromwandlersekundärstrom: 1A/3 Kanäle
  • Norm: EN 61000-6-2
  • Stoßspannung: 2kV – 1,2/50µs
  • Funkstörfeldstärke: Klasse A, B
  • Luftentladung: 8kV
  • Kontaktentladung: 4kV
Schnittstelle Anschlüsse
  • ModBus/RTU: APS V1.1b
  • Physikalische Verbindung: USB-C
  • Busteilnehmer: 16
  • Neutralleiteranschluss: 2x 0,5mm²

Anzeige

  • Bereitschaft: LED Grün
  • Fehler: LED Rot

Type designation: SL2-3x/9/RM300/RTU/3W/1/250-1

Article number: L229907003Z00

Descriptionaccording to EN60947-3, size NH2 - 400A
- 1pole switchable, DELTA-contact system
- for mounting on 3pole busbar system with 185mm centre-to-centre distance
- with v-terminal and aluminium box clamp clamp type RM300, max. clamping range: 25-300mm²
- 3 current-transformer 250-1 mounted and wired
- with integrated measuring system PLPLANO
- 3-phase for current, voltage, power, power factor, energy [kWh]
- integrated four-quadrant energy meter with detection of the energy flow direction
- secondary current detection via current transformers, if necessary for on-site exchange / retrofitting
- wired and routed to interface module
- wired with internally protected voltage tap, routed to the interface module
- Data interface protocol: ModBus / RTU
- with point-symmetrical and reverse-polarity protected plug connection
- Number of bus users: <= 16
- Installation dimension L2 until top edge of the strip (including data interface): <= 310mm
- Measuring system can be replaced without tools

Rated operating current Ie 250 A
Cable terminal V-type aluminium box terminal RM300
Poles 3
Switching mode 1pole switchable
Current measurement Integrated, 3phase
number of current-transformer 3
Primary current of current-transformer 250 A
Secondary rated current transformer Isr 1 A
Datenerfassungsmodul PLPlano

ModBus/RTU

Elektrische Kenngrößen

  • Spannungsversorgung: DC24V (+/– 6V)
  • Leistungsaufnahme: 1,5 VA
  • Innenwiderstand: L – L: 6MΩ L – N: 6MΩ
  • Messbereich L – N: AC230V (+/– 10%)
  • Messbereich L – L: AC400V (+/– 10%)
  • Frequenz: 45 – 65Hz
  • Stromwandlersekundärstrom: 1A/3 Kanäle
  • Norm: EN 61000-6-2
  • Stoßspannung: 2kV – 1,2/50µs
  • Funkstörfeldstärke: Klasse A, B
  • Luftentladung: 8kV
  • Kontaktentladung: 4kV
Schnittstelle Anschlüsse
  • ModBus/RTU: APS V1.1b
  • Physikalische Verbindung: USB-C
  • Busteilnehmer: 16
  • Neutralleiteranschluss: 2x 0,5mm²

Anzeige

  • Bereitschaft: LED Grün
  • Fehler: LED Rot

Type designation: SL2-3x/9/RM300/RTU/3W/1/400-1

Article number: L229907006Z00

Descriptionaccording to EN60947-3, size NH2 - 400A
- 1pole switchable, DELTA-contact system
- for mounting on 3pole busbar system with 185mm centre-to-centre distance
- with v-terminal and aluminium box clamp clamp type RM300, max. clamping range: 25-300mm²
- 3 current-transformer 400-1 mounted and wired
- with integrated measuring system PLPLANO
- 3-phase for current, voltage, power, power factor, energy [kWh]
- integrated four-quadrant energy meter with detection of the energy flow direction
- secondary current detection via current transformers, if necessary for on-site exchange / retrofitting
- wired and routed to interface module
- wired with internally protected voltage tap, routed to the interface module
- Data interface protocol: ModBus / RTU
- with point-symmetrical and reverse-polarity protected plug connection
- Number of bus users: <= 16
- Installation dimension L2 until top edge of the strip (including data interface): <= 310mm
- Measuring system can be replaced without tools

Rated operating current Ie: 400 A
Cable terminal: V-type aluminium box terminal RM300
Poles: 3
Switching mode: 1pole switchable
Current measurement: Integrated, 3phase
number of current-transformer: 3
Primary current of current-transformer: 400 A
Secondary rated current transformer Isr: 1 A
Datenerfassungsmodul PLPlano:

ModBus/RTU

Elektrische Kenngrößen

  • Spannungsversorgung: DC24V (+/– 6V)
  • Leistungsaufnahme: 1,5 VA
  • Innenwiderstand: L – L: 6MΩ L – N: 6MΩ
  • Messbereich L – N: AC230V (+/– 10%)
  • Messbereich L – L: AC400V (+/– 10%)
  • Frequenz: 45 – 65Hz
  • Stromwandlersekundärstrom: 1A/3 Kanäle
  • Norm: EN 61000-6-2
  • Stoßspannung: 2kV – 1,2/50µs
  • Funkstörfeldstärke: Klasse A, B
  • Luftentladung: 8kV
  • Kontaktentladung: 4kV
Schnittstelle Anschlüsse
  • ModBus/RTU: APS V1.1b
  • Physikalische Verbindung: USB-C
  • Busteilnehmer: 16
  • Neutralleiteranschluss: 2x 0,5mm²

Anzeige

  • Bereitschaft: LED Grün
  • Fehler: LED Rot

Type designation: SL2-3x/9/RM300/RTU/3W/1/400-1

Article number: L229907006Z00

Descriptionaccording to EN60947-3, size NH2 - 400A
- 1pole switchable, DELTA-contact system
- for mounting on 3pole busbar system with 185mm centre-to-centre distance
- with v-terminal and aluminium box clamp clamp type RM300, max. clamping range: 25-300mm²
- 3 current-transformer 400-1 mounted and wired
- with integrated measuring system PLPLANO
- 3-phase for current, voltage, power, power factor, energy [kWh]
- integrated four-quadrant energy meter with detection of the energy flow direction
- secondary current detection via current transformers, if necessary for on-site exchange / retrofitting
- wired and routed to interface module
- wired with internally protected voltage tap, routed to the interface module
- Data interface protocol: ModBus / RTU
- with point-symmetrical and reverse-polarity protected plug connection
- Number of bus users: <= 16
- Installation dimension L2 until top edge of the strip (including data interface): <= 310mm
- Measuring system can be replaced without tools

Rated operating current Ie 400 A
Cable terminal V-type aluminium box terminal RM300
Poles 3
Switching mode 1pole switchable
Current measurement Integrated, 3phase
number of current-transformer 3
Primary current of current-transformer 400 A
Secondary rated current transformer Isr 1 A
Datenerfassungsmodul PLPlano

ModBus/RTU

Elektrische Kenngrößen

  • Spannungsversorgung: DC24V (+/– 6V)
  • Leistungsaufnahme: 1,5 VA
  • Innenwiderstand: L – L: 6MΩ L – N: 6MΩ
  • Messbereich L – N: AC230V (+/– 10%)
  • Messbereich L – L: AC400V (+/– 10%)
  • Frequenz: 45 – 65Hz
  • Stromwandlersekundärstrom: 1A/3 Kanäle
  • Norm: EN 61000-6-2
  • Stoßspannung: 2kV – 1,2/50µs
  • Funkstörfeldstärke: Klasse A, B
  • Luftentladung: 8kV
  • Kontaktentladung: 4kV
Schnittstelle Anschlüsse
  • ModBus/RTU: APS V1.1b
  • Physikalische Verbindung: USB-C
  • Busteilnehmer: 16
  • Neutralleiteranschluss: 2x 0,5mm²

Anzeige

  • Bereitschaft: LED Grün
  • Fehler: LED Rot
Products - JEAN MÜLLER (2024)
Top Articles
Latest Posts
Article information

Author: Kareem Mueller DO

Last Updated:

Views: 6008

Rating: 4.6 / 5 (46 voted)

Reviews: 93% of readers found this page helpful

Author information

Name: Kareem Mueller DO

Birthday: 1997-01-04

Address: Apt. 156 12935 Runolfsdottir Mission, Greenfort, MN 74384-6749

Phone: +16704982844747

Job: Corporate Administration Planner

Hobby: Mountain biking, Jewelry making, Stone skipping, Lacemaking, Knife making, Scrapbooking, Letterboxing

Introduction: My name is Kareem Mueller DO, I am a vivacious, super, thoughtful, excited, handsome, beautiful, combative person who loves writing and wants to share my knowledge and understanding with you.